Analytical Services

 
Analytical Service

BioChem Laboratory, Inc. offers a wide range of testing services using USP and in-house methods.

Raw Materials Analysis
USP/CTFA/AOAC Compendial Testing
Wet Chemistry
Total Organic Carbon (TOC): Using the Shimadzu TOC WS Analyzer, the amount of carbon present in an organic compound is measured.

 
Pharmaceutical Water Testing
Full Monograph Testing
Water System Validation and Qualification
 
Pharmaceutical Water Testing
We provide customized method development services to meet the client's needs.
We have worked on method development for the following products:
Sunscreens
Foundation
Antibacterial
 


Active Tested
Octyl Methoxycinnamate Ethyly Alcohol
Octyl Salicylate Salicylic Acid (Titration)
Octocrylene Benzophenone-3
Avobenzone Allanoin
Homesalate Dimethicone
Camphor Sulfur
Menthol Benzalkoniun Chloride
Menthyl Anthranilate Benzoyl Peroxide
Titanium Dioxide Salicylic Acid (HPLC)
Zinc Oxide Hydroquinone
Colloidal Oat PCMX, Triclosan
   


ID Test Performed for following actives
Octyl Methoxycinnamate
Octyl Salicylate
Octocrylene
Avobenzone
Menthyl Anthranilate
Titanium Dioxide
Zinc Oxide
Sulfur
Benzophenone
Salicylic Acid
Homesalate
 
SHIMDZU HPLC SIL-10A SHIMDZU HPLC SIL-10A
   
SUV-VS SPECTROPHOTOMETER & BUCK M 500 INFRAED SPECTROPHOTOMETER OXYZEN COMBUSTION CHAMBER
 
 
Pharmaceutical Water Testing
Method Validation: BioChem's method validation is flexible and customizable to fit your needs. We will follow any client-supplied validation format or make modifications to our standard defined protocol as requested by the client. Method Validation is a process of conducting a number of tests intended to prove the authenticity of a method. BioChem uses the following parameters: linearity, range, precision, accuracy, and specificity. The analysis requires reference standards, placebo and/or samples with known concentrations.

Cleaning Validation: BioChem's cleaning validation is used to ensure that cleaning procedures in equipment are eliminating residues to predetermined levels of suitability. This ensures that the quality of the next product manufactured is not affected by the residue from the previous product.
 
Stability Testing & Expiration Date Validation:
Since the creation of pharmaceutical expiration dating requirements, BioChem's analytical services have been proficient in providing the storage conditions necessary to meet both regulatory and client requirements.

Stability Programs we offer include:
USP/ICH Stability Programs
Freeze-Thaw
Customer Specified Stability

 
Additional Test Services:
Thin Layer Chromatography (TLC): Using glass plates, the TLC technique is utilized to separate compounds in a product and/or determine the purity of a substance.
Flashpoint: The flash point is the lowest temperature at which the vapor formed above a pool of the liquid ignites in air at a pressure of 1 atmosphere. Flash point is a characteristic used to determine the hazardous nature of a material
SPF Testing: In-vitro SPF analyzer is used to measure the sun protection factor in the product.

 
Facilities and Equipment:
 
Our temperature and humidity-controlled chambers are continuously monitored for any environmental changes. We regularly invest in capital improvements to ensure
all our testing facilities have the latest testing equipment.
 
We provide customized method development services to meet the client's needs.
We have worked on method development for the following products:
Shimadzu GC-17 A -1
Shimadzu GC-17 A -2
Shimadzu HPLC SIL -10A
Shimadzu TOC WS Analyzer
Buck M 500 Infrared Spectrophotometer
UV-VIS Spectrophotometer
Oxygen Combustion Chamber
Stability Chamber(50°C)
• Stability Chamber(40°C)
Stability Chamber(25°C)
Optometrics SPF 290S Analyzer (INVITRO)
 
 
 
 